What solar capacity does your home in Tunisia need?

Your electricity consumption and usage habits guide sizing. The roof assessment then determines the number of panels, their layout and the appropriate inverter.

Start with a year of STEG consumption

Reading your STEG bill: distinguishing kWh, billing period and amounts.

The first useful figure is electricity consumed in kWh. Several bills reveal summer–winter variations, occupancy periods and major uses such as air conditioning, refrigeration or electric heating.

The amount in dinars provides a budget reference. To size generation, we also examine kWh consumption and billing periods. A two-month bill covers two months: spending must be compared over the same period.

Your bill is enough to get started

Upload a photo or PDF, check the detected values and prepare your assessment with our team.

Prepare my solar assessment

Consumption times matter too

Panels generate during the day. A home occupied during daylight hours, a shop with refrigeration and a business with machinery use electricity at different times. Usage distribution helps estimate how much generation will be consumed on site.

Future equipment also belongs in the study: new air conditioning, a change of building use or a business expansion. Mention these plans when requesting a quote.

Your roof determines the layout

  • Usable area: available space after allowing for obstacles and necessary access.
  • Orientation and tilt: factors affecting generation throughout the day.
  • Shading: neighbouring buildings, walls, trees or equipment on the roof.
  • Support and access: roof characteristics, fixings and working conditions.

The number of panels depends on each module's capacity and the layout. The inverter is selected to match the photovoltaic array and the site's connection.

kWc, kWh: the two units in your quote

UnitWhat it meansWhere to find it
kWcRated peak capacity of the panel array under reference conditions.Installation configuration.
kWhAmount of energy consumed or generated over a period.STEG bill and generation estimate.

What your solar assessment should help you decide

Your proposal brings together the recommended capacity, equipment, studied layout, estimated generation and underlying assumptions. The budget and financing terms complete this information to help you choose your installation.

Prepare your recent bills, a few roof photos and the building's governorate. Our team then specifies any further information and on-site checks needed.

For guidance on sizing for self-consumption: ANME's answers.

Which orientation and tilt should I choose in Tunisia?

South-facing is a benchmark to compare, and a 45° tilt is not mandatory. The choice depends on the roof, shading, wind and consumption times. The best angle for annual generation is not necessarily the best compromise for your building.

Indicative generation per kWc: comparable PVGIS simulations, in kWh/year
ConfigurationTunisSfaxTozeur
Fixed south-facing, 30°1 5831 6981 783
Fixed south-facing, 45°1 5571 6701 755
Fixed south-facing, simulated annual optimum at 33°1 5851 7001 785
Horizontal single-axis tracker1 9352 0712 171
Dual-axis tracker2 1522 3142 425

Calculations dated 30 October 2026: PVGIS 5.3, SARAH3 database, crystalline silicon, 1 kWc, entered system losses of 14 %. Ventilated fixed mounting for the first three rows. Indicative coordinates: Tunis 36,8065/10,1815; Sfax 34,7406/10,7603; Tozeur 33,9197/8,1335. Nearby shading and site-specific features require a study. Source: PVGIS, European Commission.

A tracker generates more, with different project requirements

In these simulations, a horizontal single axis raises generation by about 22 % compared with fixed south-facing at 30°, and two axes by about 36 %. The budget must also include the moving structure, motors, foundations and maintenance. Row spacing, shading, wind-safe positions and mechanical availability affect actual results.

For businesses, compare generation times too

An east/west layout may help spread generation or make use of a roof. The study compares generated kWh with the times your business uses them, alongside cost and installation constraints. Energy gains and financial gains are calculated separately.

Compare configurations in my solar assessment

Capacity and roof: your questions

Financing, generation, procedures: prepare your installation with the essential information.

Ask a question about my project
Will it work on my roof?

Orientation, tilt, area and shading matter. That is why we carry out a free technical assessment before every quote, without pricing blindly.

How does solar self-consumption work in Tunisia?

Your panels generate during the day; you use your own electricity first, and the STEG grid supplies the rest. A bidirectional meter installed by STEG measures the exchanges.

What happens at night or without sunshine?

The STEG grid takes over. Self-consumption complements the grid; it does not disconnect you from it.

Choose the right capacity for your home

Get an assessment of your consumption, a recommended capacity and a detailed budget for your installation.

CallFree quote